/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_9_Buildings.Controls.OBC.ASHRAE.G36.ThermalZones.Validation.Alarms_res.mat --tempDir=temp_Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms_fmu --startTime=0 --stopTime=7200 --timeout=50 --tolerance=1e-06 Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.fmu info: model doesn't contain any continuous state info: Result file: Buildings_9_Buildings.Controls.OBC.ASHRAE.G36.ThermalZones.Validation.Alarms_res.mat (bufferSize=1) info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.higTemAla2.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.higTemAla3.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.lowTemAla2.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.lowTemAla3.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.lowTemAla4.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.zonAla.lowTemAla5.message will not be stored in the result file, because the signal type is not supported warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Controls.OBC.ASHRAE.G36.ThermalZones.Validation.Alarms/temp_Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms_fmu/model-26b7vbci/temp/0001_Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated at time 1601.348000 not zonAla.tenMinDur4.y assert | warning | Warning: the zone CO2 concentration exceeds setpoint plus 10 error: [operator()] Timeout occurred during simulation info: 1 warnings info: 1 errors