/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_9_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Validation.Controller_res.mat --tempDir=temp_Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller_fmu --startTime=0 --stopTime=86400 --timeout=50 --tolerance=1e-06 Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Validation.Controller/temp_Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller_fmu/model-e11l5cpo/temp/0001_Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated during initialization at time 0.000000 parFanCon.ala.not11.y assert | warning | Warning: fan has been commanded OFF but still ON. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Validation.Controller/temp_Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller_fmu/model-e11l5cpo/temp/0001_Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated during initialization at time 0.000000 parFanCon.ala.not5.y assert | warning | Warning: the damper is leaking. info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_9_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Validation.Controller_res.mat (bufferSize=1) info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller.parFanCon.ala.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller.parFanCon.ala.assMes1.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller.parFanCon.ala.assMes2.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller.parFanCon.ala.assMes3.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller.parFanCon.ala.assMes4.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller.parFanCon.ala.assMes5.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller.parFanCon.ala.assMes6.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller.parFanCon.ala.assMes7.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller.parFanCon.ala.assMes8.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller.parFanCon.assMes1.message will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 2 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Validation.Controller/temp_Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller_fmu/model-e11l5cpo/temp/0001_Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_terminated state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Validation_Controller"