/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_10_Buildings.Experimental.DHC.Plants.Combined.Subsystems.Validation.ChillerHeatRecoveryGroup_res.mat --tempDir=temp_Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup_fmu --startTime=0 --stopTime=2000 --timeout=50 --tolerance=1e-06 Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.Plants.Combined.Subsystems.Validation.ChillerHeatRecoveryGroup/temp_Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup_fmu/model-hxemigkq/temp/0001_Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99: The following assertion has been violated at time 0.000000 pumChiWat.pum.etaHyd >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= pumChiWat.pum.etaHyd, has value: -6.40416e-43 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.Plants.Combined.Subsystems.Validation.ChillerHeatRecoveryGroup/temp_Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup_fmu/model-hxemigkq/temp/0001_Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99: The following assertion has been violated at time 0.000000 pumHeaWat.pum.etaHyd >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= pumHeaWat.pum.etaHyd, has value: -5.99855e-43 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.Plants.Combined.Subsystems.Validation.ChillerHeatRecoveryGroup/temp_Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup_fmu/model-hxemigkq/temp/0001_Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99: The following assertion has been violated at time 0.000000 pumConWatCon.pum.etaHyd >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= pumConWatCon.pum.etaHyd, has value: -5.31247e-43 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.Plants.Combined.Subsystems.Validation.ChillerHeatRecoveryGroup/temp_Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup_fmu/model-hxemigkq/temp/0001_Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99: The following assertion has been violated at time 0.000000 pumConWatEva.pum.etaHyd >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= pumConWatEva.pum.etaHyd, has value: -2.12237e-43 info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_10_Buildings.Experimental.DHC.Plants.Combined.Subsystems.Validation.ChillerHeatRecoveryGroup_res.mat (bufferSize=1) error: [operator()] Timeout occurred during simulation info: 4 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.Plants.Combined.Subsystems.Validation.ChillerHeatRecoveryGroup/temp_Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup_fmu/model-hxemigkq/temp/0001_Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_terminated state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.Plants.Combined.Subsystems.Validation.ChillerHeatRecoveryGroup/temp_Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup_fmu/model-hxemigkq/temp/0001_Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Experimental_DHC_Plants_Combined_Subsystems_Validation_ChillerHeatRecoveryGroup"