Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=500 stepSize=0.002 Regular simulation: ./TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.FluidDynamics.Components.Machines.test_PrescribedPump -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00246154s reading init.xml | | | | | | 0.000186931s reading info.xml | | | | | | 6.8529e-05s [ 0.0%] pre-initialization | | | | | | 0.00362406s [ 2.6%] initialization | | | | | | 0.000117871s [ 0.1%] steps | | | | | | 1.9933e-05s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 3.7192e-05s [ 0.0%] event-handling | | | | | | 0.00249072s [ 1.8%] overhead | | | | | | 0.131836s [ 95.4%] simulation | | | | | | 0.138194s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 1000 steps taken | | | | | | 1000 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.