Environment - simulationEnvironment: startTime=0 stopTime=0.1 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.0001 Regular simulation: ./Modelica_4.0.0_Modelica.Electrical.Machines.Examples.Transformers.Rectifier6pulse -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00910989s reading init.xml | | | | | | 0.00101362s reading info.xml | | | | | | 0.000445525s [ 0.5%] pre-initialization | | | | | | 0.000259797s [ 0.3%] initialization | | | | | | 9.789e-06s [ 0.0%] steps | | | | | | 0.00323927s [ 3.7%] solver (excl. callbacks) | | | | | | 0.000857702s [ 1.0%] creating output-file | | | | | | 0.0332031s [ 37.7%] event-handling | | | | | | 0.000802944s [ 0.9%] overhead | | | | | | 0.0491537s [ 55.9%] simulation | | | | | | 0.0879718s [100.0%] total | | | | | events | | | | | | 60 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 3800 steps taken | | | | | | 5134 calls of functionODE | | | | | | 1111 evaluations of jacobian | | | | | | 61 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0160866s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.