OMSimulator -r=Buildings_9_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC_res.mat --tempDir=temp_Buildings_9_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC_fmu --startTime=1.5552e+07 --stopTime=1.56384e+07 --timeout=50 --tolerance=1e-07 Buildings_9_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_Buildings_9_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC/temp_Buildings_9_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC/temp_Buildings_9_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC_fmu/model-c8932dd3" stdout | info | ... loading "tab1" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC/temp_Buildings_9_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC_fmu/model-c8932dd3/temp/fmu/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Resources/weatherdata/USA_IL_Chicago-OHare.Intl.AP.725300_TMY3.mos" warning: fmu (logStatusWarning): The following assertion has been violated during initialization at time 0.000000 assert | debug | Model error: Argument of log(hvaCon2.cooCoi.dryWetCalcs.TAirInDewPoi) was 0 should be > 0 stdout | warning | Non-Linear Solver try to handle a problem with a called assert. warning: fmu (logStatusWarning): The following assertion has been violated during initialization at time 0.000000 assert | debug | Model error: Argument of log(hvaCon2.cooCoi.dryWetCalcs.TAirInDewPoi) was 0 should be > 0 warning: fmu (logStatusWarning): The following assertion has been violated during initialization at time 0.000000 assert | debug | Model error: Argument of log(hvaCon2.cooCoi.dryWetCalcs.TAirInDewPoi) was 0 should be > 0 warning: fmu (logStatusWarning): The following assertion has been violated during initialization at time 0.000000 assert | debug | Model error: Argument of log(hvaCon2.cooCoi.dryWetCalcs.TAirInDewPoi) was 0 should be > 0 assert | debug | Solving non-linear system 2156 failed at time=0. | | | | For more information please use -lv LOG_NLS. assert | error | Failed to solve the initialization problem with global homotopy with equidistant step size. assert | debug | Unable to solve initialization problem. error: [fmi2logger] fmu (logFmi2Call): fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.fmu" error: [initialize] Initialization of system "model.root" failed error: [simulate] Model "model" is in wrong model state info: 4 warnings info: 4 errors