Environment - simulationEnvironment: startTime=0 stopTime=125 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.125 Regular simulation: ./ThermofluidStream_ThermofluidStream.Boundaries.Tests.PhaseSeperator -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | warning | The following assertion has been violated at time 26.250000 | | | | receiver.x >= 0.0 and receiver.x <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= receiver.x <= 1.0, has value: 1.36475 stdout | warning | While solving non-linear system an assertion failed at time 43.1078. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V stdout | warning | While solving non-linear system an assertion failed at time 43.1078. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V stdout | warning | While solving non-linear system an assertion failed at time 43.1078. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V assert | warning | The following assertion has been violated at time 38.625000 | | | | accumulator.x >= 0.0 and accumulator.x <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= accumulator.x <= 1.0, has value: 1.19421 assert | warning | The following assertion has been violated at time 75.187500 | | | | flowResistance.inlet.m_flow > receiver.m_flow_assert assert | error | Positive massflow at Volume outlet stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 75.156250 | | | | flowResistance.inlet.m_flow > receiver.m_flow_assert assert | error | Positive massflow at Volume outlet stdout | info | model terminate | Simulation terminated by an assert at time: 75.1562 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0102507s reading init.xml | | | | | | 0.000827352s reading info.xml | | | | | | 0.000597711s [ 0.0%] pre-initialization | | | | | | 0.00113583s [ 0.1%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.00555153s [ 0.3%] solver (excl. callbacks) | | | | | | 0.00356526s [ 0.2%] creating output-file | | | | | | 0.538988s [ 32.2%] event-handling | | | | | | 0.0125617s [ 0.8%] overhead | | | | | | 1.11152s [ 66.4%] simulation | | | | | | 1.67392s [100.0%] total | | | | | events | | | | | | 9 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1757 steps taken | | | | | | 2650 calls of functionODE | | | | | | 418 evaluations of jacobian | | | | | | 116 error test failures | | | | | | 24 convergence test failures | | | | | | 0.27441s time of jacobian evaluation