Environment - simulationEnvironment: startTime=0 stopTime=350 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.14 Regular simulation: ./ScalableTestSuite_ScalableTestSuite.Thermal.HeatConduction.Verification.OneDHeatTransferTT_Check -abortSlowSimulation -alarm=300 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00493421s reading init.xml | | | | | | 0.000359224s reading info.xml | | | | | | 0.00798032s [ 25.4%] pre-initialization | | | | | | 0.000107903s [ 0.3%] initialization | | | | | | 2.935e-06s [ 0.0%] steps | | | | | | 0.00154512s [ 4.9%] solver (excl. callbacks) | | | | | | 0.00754376s [ 24.1%] creating output-file | | | | | | -6.24687e-21s [ -0.0%] event-handling | | | | | | 0.000443906s [ 1.4%] overhead | | | | | | 0.0136603s [ 43.6%] simulation | | | | | | 0.0313994s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 140 steps taken | | | | | | 164 calls of functionODE | | | | | | 19 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 7.82602e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.