Environment - simulationEnvironment: startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS stdout | info | ... loading "EnergyPlus" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Resources/Data/ThermalZones/EnergyPlus_9_6_0/Validation/TwoIdenticalZones/TwoIdenticalZones.dat" EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2023.09.23 03:36 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD stdout | info | Output Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.inf1.y has in Modelica the unit 1. assert | warning | The following assertion has been violated at time 0.000000 | | | | zon1.duc.m_flow >= 0.0 and zon1.duc.m_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= zon1.duc.m_flow <= 100000.0, has value: -2.73576e-14 assert | warning | The following assertion has been violated at time 0.000000 | | | | zon2.duc.m_flow >= 0.0 and zon2.duc.m_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= zon2.duc.m_flow <= 100000.0, has value: -1.36788e-14 LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0113879s reading init.xml | | | | | | 0.000981301s reading info.xml | | | | | | 0.000324659s [ 0.0%] pre-initialization | | | | | | 7.53403s [ 95.5%] initialization | | | | | | 7.284e-06s [ 0.0%] steps | | | | | | 0.0200733s [ 0.3%] solver (excl. callbacks) | | | | | | 0.00405003s [ 0.1%] creating output-file | | | | | | 0.191107s [ 2.4%] event-handling | | | | | | 0.0113044s [ 0.1%] overhead | | | | | | 0.132006s [ 1.7%] simulation | | | | | | 7.8929s [100.0%] total | | | | | events | | | | | | 1007 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 15172 steps taken | | | | | | 20496 calls of functionODE | | | | | | 14000 evaluations of jacobian | | | | | | 1093 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0572393s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. Writing final SQL reports EnergyPlus Run Time=00hr 00min 0.57sec EnergyPlus Completed Successfully. stdout | info | 604200.000 Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.building: Warning from EnergyPlus: The following schedule names are "Unused Schedules". These schedules are in the idf stdout | info | 604200.000 Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. stdout | info | 604200.000 Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.building: Warning from EnergyPlus: The following week schedule names are "Unused Schedules". These schedules are in the idf stdout | info | 604200.000 Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. stdout | info | 604200.000 Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.building: Warning from EnergyPlus: The following day schedule names are "Unused Schedules". These schedules are in the idf stdout | info | 604200.000 Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used.