Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-08 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./Buildings_9_Buildings.Fluid.Movers.Validation.Pump_Nrpm_stratos -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump1.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump2.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump3.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump4.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump5.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0477307s reading init.xml | | | | | | 0.003993s reading info.xml | | | | | | 0.0016232s [ 2.9%] pre-initialization | | | | | | 0.00063451s [ 1.1%] initialization | | | | | | 4.699e-06s [ 0.0%] steps | | | | | | 0.00241635s [ 4.3%] solver (excl. callbacks) | | | | | | 0.00378308s [ 6.7%] creating output-file | | | | | | 0.000400177s [ 0.7%] event-handling | | | | | | 0.0143719s [ 25.6%] overhead | | | | | | 0.032873s [ 58.6%] simulation | | | | | | 0.0561069s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 695 steps taken | | | | | | 935 calls of functionODE | | | | | | 179 evaluations of jacobian | | | | | | 53 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000163503s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.