Environment - simulationEnvironment: startTime=0 stopTime=432000 tolerance=1e-06 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_8_Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer -abortSlowSimulation -alarm=480 -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.5.0-e579c2aa82 (No OpenGL), YMD=2023.07.29 04:50 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-LIVING ZONE-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 assert | warning | The following assertion has been violated at time 0.000000 | | | | duc.m_flow >= 0.0 and duc.m_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= duc.m_flow <= 100000.0, has value: -2.63739e-14 LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. **FATAL:Program terminates due to preceding condition. assert | debug | Failed to get variables for Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.livFlo during mode = event. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.44sec EnergyPlus Completed Successfully. stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Error from EnergyPlus: Temperature (high) out of bounds (1470.77] for zone="LIVING ZONE", for surface="LIVING:FLOOR" stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Error from EnergyPlus: Environment=SPAWN-RUNPERIOD, at Simulation time=01/01 00:30 - 00:30 stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Error from EnergyPlus: Zone="LIVING ZONE", Diagnostic Details: stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Error from EnergyPlus: ...Internal Heat Gain [8.072] W/m2 stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Error from EnergyPlus: ...Infiltration/Ventilation [0.000] m3/s stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Error from EnergyPlus: ...Mixing/Cross Mixing [0.000] m3/s stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Error from EnergyPlus: ...Zone is not part of HVAC controlled system. stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Error from EnergyPlus: Temperature (high) out of bounds [1470.77] for zone="LIVING ZONE", for surface="LIVING:FLOOR" stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Error from EnergyPlus: Environment=SPAWN-RUNPERIOD, at Simulation time=01/01 00:30 - 00:30 stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Fatal from EnergyPlus: Program terminates due to preceding condition. stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Fatal from EnergyPlus: Program terminates due to preceding condition. stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: Calculated Relative Humidity out of range (PsyRhFnTdbWPb) stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: Routine=Unknown, Environment=SPAWN-RUNPERIOD, at Simulation time=01/01 00:30 - 00:30 stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: Dry-Bulb= -20.63 Humidity Ratio= 2.083E-003 Calculated Relative Humidity [%]= 341.44 stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: Relative Humidity being reset to 100.0% stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Error from EnergyPlus: ** Severe ** Temperature (high) out of bounds for zone=LIVING ZONE for surface=LIVING:FLOOR stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Error from EnergyPlus: stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: ** Warning ** Calculated Relative Humidity out of range (PsyRhFnTdbWPb) stdout | info | 1800.000 Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingWithGroundHeatTransfer.building: Warning from EnergyPlus: