OMSimulator --tempDir=temp_Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Subsystems_Validation_Chiller_fmu --startTime=0 --stopTime=5000 --timeout=50 --tolerance=1e-06 Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Subsystems_Validation_Chiller.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Subsystems_Validation_Chiller_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Generation5.Subsystems.Validation.Chiller/temp_Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Subsystems_Validation_Chiller_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Generation5.Subsystems.Validation.Chiller" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Generation5.Subsystems.Validation.Chiller/temp_Buildings_8_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Generation5_Subsystems_Validation_Chiller_fmu/model-ssiez48u" warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Fluid/Interfaces.mo:13: The following assertion has been violated at time 0.000000 (if chi.valEva.res1.m_flow_nominal_pos > 1e-15 then chi.valEva.res1.m_flow_nominal_pos else 1.0) >= -100000.0 and (if chi.valEva.res1.m_flow_nominal_pos > 1e-15 then chi.valEva.res1.m_flow_nominal_pos else 1.0) <= 0.0 assert | warning | Nominal variable violating min/max constraint: -100000.0 <= evaWat.ports[2].m_flow <= 0.0, has value: 1 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Fluid/Interfaces.mo:13: The following assertion has been violated at time 0.000000 (if chi.valCon.res1.m_flow_nominal_pos > 1e-15 then chi.valCon.res1.m_flow_nominal_pos else 1.0) >= -100000.0 and (if chi.valCon.res1.m_flow_nominal_pos > 1e-15 then chi.valCon.res1.m_flow_nominal_pos else 1.0) <= 0.0 assert | warning | Nominal variable violating min/max constraint: -100000.0 <= conWat.ports[2].m_flow <= 0.0, has value: 1