Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection,fileNamePrefix="Buildings_6_0_0_Buildings_ThermalZones_Detailed_Examples_FFD_ForcedConvection",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.01126/0.01126, allocations: 105.8 kB / 15.06 MB, free: 6.027 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001293/0.001293, allocations: 180.8 kB / 15.95 MB, free: 5.953 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 2.009/2.009, allocations: 194.5 MB / 211.2 MB, free: 11.24 MB / 170.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 2.335/2.335, allocations: 236.1 MB / 492.6 MB, free: 11.39 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0007023/0.0007025, allocations: 12 kB / 0.587 GB, free: 2.117 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7115/0.7122, allocations: 98.72 MB / 0.6834 GB, free: 16.73 MB / 0.5261 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection): time 0.3247/1.037, allocations: 174.7 MB / 0.8541 GB, free: 15.29 MB / 0.6823 GB Notification: Performance of NFInst.instExpressions: time 0.082/1.119, allocations: 26.35 MB / 0.8798 GB, free: 4.887 MB / 0.698 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01298/1.132, allocations: 210.6 kB / 0.88 GB, free: 4.68 MB / 0.698 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): roo.bouConExt.conPar.layers.nLay which gives dimensions of array: material. Array dimensions must be known at compile time. Notification: Performance of FrontEnd: time 0.009004/1.141, allocations: 1.891 MB / 0.8818 GB, free: 2.781 MB / 0.698 GB