OMSimulator --tempDir=temp_Buildings_6_0_0_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_FixedApproachDryBulb_fmu --startTime=1.5552e+07 --stopTime=1.5984e+07 --timeout=50 --tolerance=1e-06 Buildings_6_0_0_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_FixedApproachDryBulb.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_Buildings_6_0_0_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_FixedApproachDryBulb_fmu" info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_6.0.0_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachDryBulb/temp_Buildings_6_0_0_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_FixedApproachDryBulb_fmu" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_6.0.0_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachDryBulb" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_6.0.0_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachDryBulb/temp_Buildings_6_0_0_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_FixedApproachDryBulb_fmu/model-vg4nn26k" stdout | info | ... loading "tab1" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_6.0.0_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachDryBulb/temp_Buildings_6_0_0_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_FixedApproachDryBulb_fmu/model-vg4nn26k/temp/fmu/resources/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Resources/weatherdata/USA_CA_San.Francisco.Intl.AP.724940_TMY3.mos" warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352: The following assertion has been violated during initialization at time 0.000000 pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Utilities/Psychrometrics/TWetBul_TDryBulPhi.mo:40: The following assertion has been violated at time 0.000000 weaDat.tWetBul_TDryBulXi.XiSat >= 0.0 and weaDat.tWetBul_TDryBulXi.XiSat <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.tWetBul_TDryBulXi.XiSat <= 1.0, has value: -1.64772 warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Utilities/Psychrometrics/TWetBul_TDryBulPhi.mo:41: The following assertion has been violated at time 0.000000 weaDat.tWetBul_TDryBulXi.XiSatRefIn >= 0.0 and weaDat.tWetBul_TDryBulXi.XiSatRefIn <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.tWetBul_TDryBulXi.XiSatRefIn <= 1.0, has value: -0.61881 info: maximum step size for 'model.root': -1555199.900000 [CVODE ERROR] CVodeSetMaxStep hmax < 0 illegal. error: [initialize] SUNDIALS_ERROR: CVodeSetMaxStep() failed with flag = -22 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.fmu.weaDat.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.fmu.weaDat.datRea.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.fmu.weaDat.datRea1.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.fmu.weaDat.datRea1.tableName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 595 NumRhsEvals = 872 NumLinSolvSetups = 204 NumNonlinSolvIters = 871 NumNonlinSolvConvFails = 0 NumErrTestFails = 66 info: 3 warnings info: 1 errors