startTime=0 stopTime=10 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.004 Regular simulation: ./ModelicaTest_3.2.1_ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpDefaultCV -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated at time 0.000000 | | | | pump.delta_head_init >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= pump.delta_head_init, has value: -50.1499 LOG_SUCCESS | info | The initialization finished successfully with 4 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00507244s reading init.xml | | | | | | 0.000431629s reading info.xml | | | | | | 0.000118683s [ 0.0%] pre-initialization | | | | | | 0.00209919s [ 0.3%] initialization | | | | | | 8.4749e-05s [ 0.0%] steps | | | | | | 4.4813e-05s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0319245s [ 4.7%] event-handling | | | | | | 0.0155834s [ 2.3%] overhead | | | | | | 0.632583s [ 92.7%] simulation | | | | | | 0.682438s [100.0%] total | | | | | events | | | | | | 3 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 11457 steps taken | | | | | | 11457 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.