startTime=0 stopTime=360 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.144 Regular simulation: ./Buildings_latest_Buildings.Fluid.HeatExchangers.Validation.WetCoilDiscretizedInitialization -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully with 4 homotopy steps. assert | warning | The following assertion has been violated at time 60.768000 | | | | hexSteSta.SHR >= 0.0 and hexSteSta.SHR <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= hexSteSta.SHR <= 1.0, has value: -2.91038e-11 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.147773s reading init.xml | | | | | | 0.0103191s reading info.xml | | | | | | 0.00361202s [ 0.7%] pre-initialization | | | | | | 0.00204512s [ 0.4%] initialization | | | | | | 5.868e-05s [ 0.0%] steps | | | | | | 0.00841475s [ 1.7%] solver (excl. callbacks) | | | | | | 0.0117704s [ 2.4%] creating output-file | | | | | | 0.00251543s [ 0.5%] event-handling | | | | | | 0.115559s [ 23.1%] overhead | | | | | | 0.356304s [ 71.2%] simulation | | | | | | 0.500279s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 443 steps taken | | | | | | 689 calls of functionODE | | | | | | 118 evaluations of jacobian | | | | | | 24 error test failures | | | | | | 2 convergence test failures | | | | | | 0.00570828s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.