startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_9_Buildings.Obsolete.DistrictHeatingCooling.SubStations.Validation.HeatingSubstation -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | subSta.pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00619008s reading init.xml | | | | | | 0.000830137s reading info.xml | | | | | | 0.000248817s [ 0.7%] pre-initialization | | | | | | 0.000211166s [ 0.6%] initialization | | | | | | 5.461e-06s [ 0.0%] steps | | | | | | 2.4385e-05s [ 0.1%] solver (excl. callbacks) | | | | | | 0.00110963s [ 2.9%] creating output-file | | | | | | 0.000707111s [ 1.8%] event-handling | | | | | | 0.0140304s [ 36.7%] overhead | | | | | | 0.0219151s [ 57.3%] simulation | | | | | | 0.0382521s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 10005 steps taken | | | | | | 10005 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.