Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneCompareZoneTemperatureOutput.conf.json loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneCompareZoneTemperatureOutput,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneCompareZoneTemperatureOutput") translateModel(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneCompareZoneTemperatureOutput,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneCompareZoneTemperatureOutput") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.666/2.666, allocations: 287.5 MB / 302.5 MB, free: 8.301 MB / 234.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001531/0.001531, allocations: 177.2 kB / 371 MB, free: 10.79 MB / 298.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.009/2.009, allocations: 205.4 MB / 0.6297 GB, free: 10.52 MB / 458.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001092/0.001092, allocations: 90.86 kB / 0.743 GB, free: 6.512 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0005018/0.0005015, allocations: 11.48 kB / 0.8658 GB, free: 141.1 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2345/0.235, allocations: 115.3 MB / 0.9784 GB, free: 28.3 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.908/7.143, allocations: 2.113 GB / 3.091 GB, free: 171.8 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003699/7.144, allocations: 106 kB / 3.091 GB, free: 171.8 MB / 0.948 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneCompareZoneTemperatureOutput Notification: Performance of FrontEnd: time 0.5146/7.659, allocations: 157 MB / 3.245 GB, free: 20.2 MB / 0.948 GB