Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOutputVariable.conf.json loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOutputVariable,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOutputVariable") translateModel(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOutputVariable,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOutputVariable") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.661/2.661, allocations: 287.5 MB / 302.4 MB, free: 8.23 MB / 234.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001483/0.001475, allocations: 178.1 kB / 371 MB, free: 10.8 MB / 298.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.058/2.058, allocations: 205.4 MB / 0.6297 GB, free: 10.52 MB / 458.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001159/0.001158, allocations: 94.91 kB / 0.743 GB, free: 6.523 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0005014/0.0005013, allocations: 13.34 kB / 0.8658 GB, free: 141 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2239/0.2245, allocations: 115.3 MB / 0.9784 GB, free: 28.32 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.827/7.051, allocations: 2.074 GB / 3.053 GB, free: 200 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003174/7.052, allocations: 97.86 kB / 3.053 GB, free: 199.9 MB / 0.948 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/EnergyPlus/OutputVariable.mo:39:3-69:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOutputVariable Notification: Performance of FrontEnd: time 0.138/7.19, allocations: 36.7 MB / 3.089 GB, free: 169 MB / 0.948 GB