startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_8.0.0_Buildings.Obsolete.DistrictHeatingCooling.Plants.Validation.Plant_T_ClosedLoop -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0153086s reading init.xml | | | | | | 0.0014026s reading info.xml | | | | | | 0.000109365s [ 0.2%] pre-initialization | | | | | | 0.000190147s [ 0.3%] initialization | | | | | | 2.5418e-05s [ 0.0%] steps | | | | | | 0.00279946s [ 5.1%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00201308s [ 3.7%] event-handling | | | | | | 0.0162664s [ 29.6%] overhead | | | | | | 0.0334632s [ 61.0%] simulation | | | | | | 0.054867s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1056 steps taken | | | | | | 1426 calls of functionODE | | | | | | 272 evaluations of jacobian | | | | | | 73 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00113508s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.