Regular simulation: ./Buildings_7.0.0_Buildings.Experimental.DistrictHeatingCooling.SubStations.Validation.CoolingSubstation -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | subSta.pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00991679s reading init.xml | | | | | | 0.00107085s reading info.xml | | | | | | 7.5532e-05s [ 0.1%] pre-initialization | | | | | | 0.000236414s [ 0.4%] initialization | | | | | | 6.803e-06s [ 0.0%] steps | | | | | | 0.000103764s [ 0.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0s [ 0.0%] event-handling | | | | | | 0.0138965s [ 26.0%] overhead | | | | | | 0.0391454s [ 73.2%] simulation | | | | | | 0.0534867s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 10005 steps taken | | | | | | 10005 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.