Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.Examples.MixedAirFreeResponse.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Examples.MixedAirFreeResponse,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.ThermalZones.Detailed.Examples.MixedAirFreeResponse") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.01495/0.01495, allocations: 110.2 kB / 15.05 MB, free: 5.965 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001764/0.001764, allocations: 183.8 kB / 15.94 MB, free: 5.93 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 1.956/1.956, allocations: 194.5 MB / 211.3 MB, free: 11.03 MB / 170.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 2.128/2.128, allocations: 236.2 MB / 492.6 MB, free: 11.33 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0004612/0.0004614, allocations: 8 kB / 0.5869 GB, free: 2.168 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6054/0.6059, allocations: 98.7 MB / 0.6833 GB, free: 16.65 MB / 0.5261 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.134/6.74, allocations: 2.317 GB / 3 GB, free: 148.2 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002633/6.74, allocations: 102 kB / 3.001 GB, free: 148.1 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Examples.MixedAirFreeResponse Notification: Performance of FrontEnd: time 1.307/8.047, allocations: 231 MB / 3.226 GB, free: 203 MB / 0.823 GB