Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneZoneOneOutputVariableSummer",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneZoneOneOutputVariableSummer",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.595/2.595, allocations: 393.5 MB / 408.4 MB, free: 11.03 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001219/0.001219, allocations: 176 kB / 0.4901 GB, free: 2.258 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.662/1.662, allocations: 223.1 MB / 0.7992 GB, free: 14.75 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009582/0.0009583, allocations: 99.19 kB / 0.9396 GB, free: 1.93 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.0003822/0.0003822, allocations: 10.44 kB / 1.09 GB, free: 216.1 MB / 0.823 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3427/0.3431, allocations: 143 MB / 1.229 GB, free: 105.7 MB / 0.823 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.613/6.956, allocations: 1.96 GB / 3.19 GB, free: 332.4 MB / 1.167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003796/6.956, allocations: 103.5 kB / 3.19 GB, free: 332.4 MB / 1.167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/ThermalZones/EnergyPlus_9_6_0/BaseClasses/ThermalZoneAdapter.mo:101:3-131:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer Notification: Performance of FrontEnd: time 0.3669/7.323, allocations: 159 MB / 3.345 GB, free: 288.9 MB / 1.167 GB