Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneEnvironmentOutputVariable.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneEnvironmentOutputVariable,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneEnvironmentOutputVariable",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneEnvironmentOutputVariable,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneEnvironmentOutputVariable",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.733/2.733, allocations: 393.5 MB / 408.4 MB, free: 10.99 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001464/0.001464, allocations: 179.6 kB / 0.4901 GB, free: 2.242 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.827/1.827, allocations: 223.1 MB / 0.7992 GB, free: 15.57 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001086/0.001086, allocations: 97.2 kB / 0.9396 GB, free: 2.77 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.0004359/0.0004362, allocations: 8.375 kB / 1.09 GB, free: 212.8 MB / 0.8073 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3566/0.3571, allocations: 143 MB / 1.229 GB, free: 85.34 MB / 0.8073 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.238/5.595, allocations: 1.734 GB / 2.963 GB, free: 195 MB / 1.167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002611/5.596, allocations: 98.5 kB / 2.963 GB, free: 195 MB / 1.167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/ThermalZones/EnergyPlus_9_6_0/OutputVariable.mo:39:3-71:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneEnvironmentOutputVariable Notification: Performance of FrontEnd: time 0.08545/5.681, allocations: 35.86 MB / 2.998 GB, free: 164.7 MB / 1.167 GB