Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case980FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case980FF,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case980FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case980FF,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case980FF",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.456/2.456, allocations: 393.5 MB / 408.4 MB, free: 11.07 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001698/0.001698, allocations: 193.9 kB / 0.4901 GB, free: 2.25 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.746/1.746, allocations: 223.1 MB / 0.7992 GB, free: 14.72 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001111/0.001111, allocations: 108.7 kB / 0.9396 GB, free: 1.84 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.0004374/0.0004375, allocations: 18.09 kB / 1.09 GB, free: 216.3 MB / 0.823 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3644/0.3649, allocations: 143 MB / 1.229 GB, free: 105.6 MB / 0.823 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.574/6.939, allocations: 2.095 GB / 3.324 GB, free: 349.5 MB / 1.167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0005844/6.94, allocations: 116.3 kB / 3.324 GB, free: 349.5 MB / 1.167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case980FF Notification: Performance of FrontEnd: time 2.519/9.459, allocations: 0.683 GB / 4.007 GB, free: 101.1 MB / 1.167 GB