Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoDifferentOutputVariables.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoDifferentOutputVariables,fileNamePrefix="Buildings_8_Buildings_ThermalZones_EnergyPlus_Validation_OutputVariable_OneZoneTwoDifferentOutputVariables",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoDifferentOutputVariables,fileNamePrefix="Buildings_8_Buildings_ThermalZones_EnergyPlus_Validation_OutputVariable_OneZoneTwoDifferentOutputVariables",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.676/1.676, allocations: 292.6 MB / 307.5 MB, free: 5.207 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001202/0.001202, allocations: 187.5 kB / 377.1 MB, free: 1.516 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.946/1.946, allocations: 205.4 MB / 0.6366 GB, free: 8.629 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.000947/0.0009471, allocations: 86.36 kB / 0.7509 GB, free: 62.88 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.000464/0.0004645, allocations: 8 kB / 0.8749 GB, free: 11.12 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.313/0.3135, allocations: 116.3 MB / 0.9884 GB, free: 6.668 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.327/7.641, allocations: 2.114 GB / 3.102 GB, free: 66.93 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004238/7.641, allocations: 102.8 kB / 3.103 GB, free: 66.83 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoDifferentOutputVariables Notification: Performance of FrontEnd: time 1.257/8.899, allocations: 155.6 MB / 3.254 GB, free: 230.3 MB / 0.948 GB