Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600,fileNamePrefix="Buildings_7_0_0_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case600",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.191/2.191, allocations: 251 MB / 265.9 MB, free: 11.68 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001717/0.001717, allocations: 185.6 kB / 325.5 MB, free: 2.875 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.359/2.359, allocations: 205.4 MB / 0.5764 GB, free: 20.83 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001104/0.001104, allocations: 96.61 kB / 0.6809 GB, free: 13.65 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004871/0.0004872, allocations: 9.125 kB / 0.795 GB, free: 135.5 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2275/0.228, allocations: 106.3 MB / 0.8988 GB, free: 65.46 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.703/7.931, allocations: 2.365 GB / 3.263 GB, free: 145.4 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0005738/7.931, allocations: 115 kB / 3.264 GB, free: 145.3 MB / 0.8855 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:198:3-206:69:writable] Error: Variable staRes: In modifier (minT(Min = 254.35), class or component Min), class or component minT not found in . Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600 Notification: Performance of FrontEnd: time 1.447/9.378, allocations: 225.6 MB / 3.484 GB, free: 215.8 MB / 0.8855 GB