Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_VariableSpeed.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_VariableSpeed,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_HeatPumps_Validation_ScrollWaterToWater_VariableSpeed",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.337/2.337, allocations: 251 MB / 265.9 MB, free: 11.68 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001757/0.001756, allocations: 179 kB / 325.5 MB, free: 2.895 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.388/2.388, allocations: 205.4 MB / 0.5764 GB, free: 21.19 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001121/0.001121, allocations: 99.14 kB / 0.6809 GB, free: 14.06 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0005338/0.0005338, allocations: 13.06 kB / 0.795 GB, free: 135.7 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2367/0.2372, allocations: 106.3 MB / 0.8988 GB, free: 65.96 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.299/1.536, allocations: 415.3 MB / 1.304 GB, free: 3.805 MB / 0.8073 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000354/1.537, allocations: 98.39 kB / 1.305 GB, free: 3.754 MB / 0.8073 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/specificIsobaricHeatCapacityVap_Tv.mo:42:3-42:35:writable] Error: Variable A not found in scope Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/isentropicExponentVap_Tv.mo:20:3-20:84:writable] Error: Class Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv not found in scope Buildings.Fluid.HeatPumps.Compressors.ScrollCompressor$heaPum$com.ref.isentropicExponentVap_Tv (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_VariableSpeed Notification: Performance of FrontEnd: time 1.065/2.601, allocations: 118.7 MB / 1.42 GB, free: 294.5 MB / 0.8855 GB