Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection,fileNamePrefix="Buildings_6_0_0_Buildings_Fluid_HeatPumps_Validation_ScrollWaterToWater_TemperatureProtection",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.01141/0.01141, allocations: 108.2 kB / 15.05 MB, free: 5.934 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001247/0.001247, allocations: 183.4 kB / 15.94 MB, free: 5.898 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 2.028/2.028, allocations: 194.6 MB / 211.3 MB, free: 11.06 MB / 170.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 2.373/2.373, allocations: 236.2 MB / 492.6 MB, free: 11.37 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0006654/0.0006658, allocations: 12 kB / 0.587 GB, free: 2.09 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7919/0.7926, allocations: 98.71 MB / 0.6834 GB, free: 16.81 MB / 0.5261 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.365/2.157, allocations: 407.2 MB / 1.081 GB, free: 41.71 MB / 0.7292 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003502/2.158, allocations: 99.64 kB / 1.081 GB, free: 41.66 MB / 0.7292 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Media/Refrigerants/R410A/specificIsobaricHeatCapacityVap_Tv.mo:42:3-42:35:writable] Error: Variable A not found in scope Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Media/Refrigerants/R410A/isentropicExponentVap_Tv.mo:20:3-20:84:writable] Error: Class Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv not found in scope Buildings.Fluid.HeatPumps.Compressors.ScrollCompressor$heaPum$com.ref.isentropicExponentVap_Tv (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection Notification: Performance of FrontEnd: time 0.4003/2.558, allocations: 116.8 MB / 1.195 GB, free: 14.7 MB / 0.8073 GB