Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature,fileNamePrefix="Buildings_latest_Buildings_Fluid_Chillers_Validation_Carnot_TEva_HighTemperature",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadModel(Buildings): time 4.375/4.375, allocations: 464.6 MB / 476.8 MB, free: 2.184 MB / 378.7 MB Notification: Performance of FrontEnd - loaded program: time 5.223e-05/5.238e-05, allocations: 4 kB / 0.5732 GB, free: 5.625 MB / 458.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2459/0.246, allocations: 107.2 MB / 0.6778 GB, free: 10.27 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.337/1.583, allocations: 415 MB / 1.083 GB, free: 3.387 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000371/1.584, allocations: 87.7 kB / 1.083 GB, free: 3.344 MB / 0.8698 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings latest/Fluid/Chillers/Examples/Carnot_TEva.mo:19:3-33:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature Notification: Performance of FrontEnd: time 0.9302/2.514, allocations: 82.42 MB / 1.164 GB, free: 304.4 MB / 0.8855 GB