Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|roo.weaBus.TDryBul|roo.air.vol.T",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition") translateModel(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|roo.weaBus.TDryBul|roo.air.vol.T",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.379/2.379, allocations: 390.3 MB / 402.8 MB, free: 6.633 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001109/0.001109, allocations: 180.8 kB / 496.1 MB, free: 12.85 MB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.963/1.963, allocations: 221.3 MB / 0.7915 GB, free: 5.391 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001115/0.001114, allocations: 99.81 kB / 0.9318 GB, free: 5.695 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 3.289e-05/3.34e-05, allocations: 7.984 kB / 1.079 GB, free: 140.5 MB / 0.7292 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3643/0.3643, allocations: 143 MB / 1.219 GB, free: 13.5 MB / 0.7448 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.661/7.025, allocations: 2.063 GB / 3.282 GB, free: 244.3 MB / 1.167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002778/7.025, allocations: 99.94 kB / 3.282 GB, free: 244.2 MB / 1.167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:246:11-246:38:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition Notification: Performance of FrontEnd: time 0.54/7.565, allocations: 242.1 MB / 3.519 GB, free: 124 kB / 1.167 GB