Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.IdealHeatingCoolingSpring.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.IdealHeatingCoolingSpring,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|flo.TAirCor|flo.TAirSou|flo.TAirNor|flo.TAirEas|flo.TAirWes|hea.1..conPID.y|hea.2..conPID.y|hea.3..conPID.y|hea.4..conPID.y|hea.5..conPID.y|flo.sou.heaPorAir.Q_flow|flo.eas.heaPorAir.Q_flow|flo.nor.heaPorAir.Q_flow|flo.wes.heaPorAir.Q_flow|flo.cor.heaPorAir.Q_flow|EHea.y|ECoo.y|coo.1..conPID.y|coo.2..conPID.y|coo.3..conPID.y|coo.4..conPID.y|coo.5..conPID.y",fileNamePrefix="Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.IdealHeatingCoolingSpring") translateModel(Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.IdealHeatingCoolingSpring,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|flo.TAirCor|flo.TAirSou|flo.TAirNor|flo.TAirEas|flo.TAirWes|hea.1..conPID.y|hea.2..conPID.y|hea.3..conPID.y|hea.4..conPID.y|hea.5..conPID.y|flo.sou.heaPorAir.Q_flow|flo.eas.heaPorAir.Q_flow|flo.nor.heaPorAir.Q_flow|flo.wes.heaPorAir.Q_flow|flo.cor.heaPorAir.Q_flow|EHea.y|ECoo.y|coo.1..conPID.y|coo.2..conPID.y|coo.3..conPID.y|coo.4..conPID.y|coo.5..conPID.y",fileNamePrefix="Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.IdealHeatingCoolingSpring") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.364/2.364, allocations: 387.1 MB / 399.7 MB, free: 9.461 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001209/0.001209, allocations: 180 kB / 492.3 MB, free: 0.5977 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.836/1.836, allocations: 221.3 MB / 0.7871 GB, free: 12.86 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001329/0.001328, allocations: 94.08 kB / 0.9267 GB, free: 13.94 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 5.587e-05/5.606e-05, allocations: 7.938 kB / 1.073 GB, free: 180.4 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3623/0.3624, allocations: 142.3 MB / 1.212 GB, free: 38.52 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.199/6.561, allocations: 1.98 GB / 3.193 GB, free: 347.1 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002777/6.561, allocations: 99.94 kB / 3.193 GB, free: 347 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/ThermalZones/EnergyPlus_9_6_0/BaseClasses/ThermalZoneAdapter.mo:101:3-131:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.IdealHeatingCoolingSpring Notification: Performance of FrontEnd: time 6.648/13.21, allocations: 1.653 GB / 4.845 GB, free: 11.05 MB / 1.198 GB