Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week") Notification: Performance of loadModel(Buildings): time 3.728/3.728, allocations: 432.7 MB / 445.3 MB, free: 15.66 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 2.947e-05/2.962e-05, allocations: 4.109 kB / 0.5383 GB, free: 10.24 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1674/0.1674, allocations: 98.72 MB / 0.6347 GB, free: 1.875 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.6777/0.8451, allocations: 156.6 MB / 0.7876 GB, free: 56.01 MB / 0.6511 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000324/0.8455, allocations: 108.8 kB / 0.7877 GB, free: 56.01 MB / 0.6511 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/GroundTemperatureResponse.mo:8:3-10:87:writable] Error: Array equation has unknown size in groTemRes.borFieDat.conDat.cooBor=borFieDat.conDat.cooBor. Error: Internal error - InstUtil.moveBindings: Mismatched number of equations and variables. Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week Notification: Performance of FrontEnd: time 0.2336/1.079, allocations: 33.91 MB / 0.8209 GB, free: 53.04 MB / 0.6511 GB