Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary") Notification: Performance of loadModel(Buildings): time 3.777/3.777, allocations: 432.7 MB / 445.3 MB, free: 15.68 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 2.733e-05/2.746e-05, allocations: 7.609 kB / 0.5383 GB, free: 10.31 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1692/0.1693, allocations: 98.72 MB / 0.6347 GB, free: 1.941 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.543/1.712, allocations: 0.4907 GB / 1.125 GB, free: 210.9 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002764/1.712, allocations: 115.5 kB / 1.126 GB, free: 210.9 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Applications/DataCenters/ChillerCooled/Equipment/IntegratedPrimarySecondary.mo:121:11-121:21:writable] Error: Type mismatch in binding pressure = Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure({0, 0}, {0, 0}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[2] V_flow; Real(min = 0.0, displayUnit = "Pa", quantity = "Pressure", unit = "Pa")[2] dp; end Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure Integer[2] V_flow; Integer[2] dp; end Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary Notification: Performance of FrontEnd: time 10.52/12.23, allocations: 2.29 GB / 3.416 GB, free: 86.09 MB / 0.948 GB