OMSimulator --tempDir=temp_TAeZoSysPro_TAeZoSysPro_HeatTransfer_Examples_Room_with_wood_burner_fmu --startTime=0 --stopTime=7200 --timeout=50 --tolerance=1e-06 TAeZoSysPro_TAeZoSysPro_HeatTransfer_Examples_Room_with_wood_burner.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_TAeZoSysPro_TAeZoSysPro_HeatTransfer_Examples_Room_with_wood_burner_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/TAeZoSysPro_TAeZoSysPro.HeatTransfer.Examples.Room_with_wood_burner/temp_TAeZoSysPro_TAeZoSysPro_HeatTransfer_Examples_Room_with_wood_burner_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/TAeZoSysPro_TAeZoSysPro.HeatTransfer.Examples.Room_with_wood_burner" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/TAeZoSysPro_TAeZoSysPro.HeatTransfer.Examples.Room_with_wood_burner/temp_TAeZoSysPro_TAeZoSysPro_HeatTransfer_Examples_Room_with_wood_burner_fmu/model-t0bvm6u5" stdout | info | iteration to converge on Fview: 8 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/vertical_plate_ASHRAE.mo:21: the Rayleigh number > 10^12 is out of the range of the correlation warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/ceiling_ASHRAE.mo:49: the Rayleigh number >1.5*10^9 is out of the range of the correlation warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/ground_ASHRAE.mo:54: the Rayleigh number >10^9 is out of the range of the correlation warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/ground_ASHRAE.mo:48: the Rayleigh number >1.5*10^9 is out of the range of the correlation warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/vertical_plate_ASHRAE.mo:20: the Rayleigh number < 10^9 is out of the range of the correlation. => Correlation extrapolated warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/BasesClasses/FreeConvection_dT_decoupled.mo:20: The following assertion has been violated at time 0.000000 wood_burner.convection_emitter.T_mean >= 273.15 and wood_burner.convection_emitter.T_mean <= 373.15 assert | warning | Variable violating min/max constraint: 273.15 <= wood_burner.convection_emitter.T_mean <= 373.15, has value: 563.628 info: maximum step size for 'model.root': 0.100000 info: Result file: model_res.mat (bufferSize=10) info: Final Statistics for 'model.root': NumSteps = 72026 NumRhsEvals = 72051 NumLinSolvSetups = 3612 NumNonlinSolvIters = 72050 NumNonlinSolvConvFails = 0 NumErrTestFails = 1 info: 6 warnings info: 0 errors