Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.TwoBusesShuntTransmissionLine.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: "" <> buildModelFMU(PowerGrids.Electrical.Test.TwoBusesShuntTransmissionLine,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_TwoBusesShuntTransmissionLine",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerGrids.Electrical.Test.TwoBusesShuntTransmissionLine,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_TwoBusesShuntTransmissionLine",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001653/0.001653, allocations: 174.6 kB / 12.73 MB, free: 2.59 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.701/1.701, allocations: 205.2 MB / 218.5 MB, free: 9.207 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008317/0.0008317, allocations: 79.53 kB / 266.6 MB, free: 9.266 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo): time 0.05901/0.05901, allocations: 14.03 MB / 328.7 MB, free: 11.04 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 2.878e-05/2.881e-05, allocations: 4 kB / 387.8 MB, free: 68.15 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1015/0.1016, allocations: 51.11 MB / 438.9 MB, free: 17.03 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.397/0.4986, allocations: 84.37 MB / 0.511 GB, free: 9.988 MB / 330.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0001989/0.4989, allocations: 75.05 kB / 0.511 GB, free: 9.977 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBusA$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.TwoBusesShuntTransmissionLine Notification: Performance of FrontEnd: time 0.01224/0.5111, allocations: 5.589 MB / 0.5165 GB, free: 7.395 MB / 330.7 MB