Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.LoadImpedancePQ.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: "" <> buildModelFMU(PowerGrids.Electrical.Test.LoadImpedancePQ,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_LoadImpedancePQ",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerGrids.Electrical.Test.LoadImpedancePQ,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_LoadImpedancePQ",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00132/0.00132, allocations: 174.7 kB / 12.73 MB, free: 2.59 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.958/1.958, allocations: 205.2 MB / 218.5 MB, free: 9.219 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001482/0.001483, allocations: 97 kB / 266.6 MB, free: 9.262 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo): time 0.06119/0.06119, allocations: 14.03 MB / 328.7 MB, free: 11.03 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 4.098e-05/4.113e-05, allocations: 4 kB / 387.8 MB, free: 68.14 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.09745/0.09752, allocations: 51.11 MB / 438.9 MB, free: 17.02 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.438/0.5356, allocations: 83.55 MB / 0.5102 GB, free: 10.23 MB / 330.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002319/0.5358, allocations: 76.11 kB / 0.5103 GB, free: 10.22 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$load1$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.LoadImpedancePQ Notification: Performance of FrontEnd: time 0.0126/0.5485, allocations: 5.153 MB / 0.5153 GB, free: 8.309 MB / 330.7 MB