Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Modelica_trunk_Modelica.Electrical.Batteries.Examples.BatteryDischargeCharge.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex trunk/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices trunk/package.mo", uses=false) Using package ModelicaServices with version trunk (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices trunk/package.mo) Using package Modelica with version trunk (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/package.mo) Using package Complex with version trunk (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex trunk/package.mo) Running command: "" <> buildModelFMU(Modelica.Electrical.Batteries.Examples.BatteryDischargeCharge,fileNamePrefix="Modelica_trunk_Modelica_Electrical_Batteries_Examples_BatteryDischargeCharge",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Modelica.Electrical.Batteries.Examples.BatteryDischargeCharge,fileNamePrefix="Modelica_trunk_Modelica_Electrical_Batteries_Examples_BatteryDischargeCharge",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex trunk/package.mo): time 0.001267/0.001267, allocations: 197 kB / 14.16 MB, free: 1.16 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/package.mo): time 1.404/1.404, allocations: 225.4 MB / 240.1 MB, free: 15.08 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices trunk/package.mo): time 0.0009826/0.0009825, allocations: 92.75 kB / 292.1 MB, free: 6.035 MB / 234.7 MB Notification: Performance of FrontEnd - loaded program: time 2.58e-05/2.582e-05, allocations: 4 kB / 350.6 MB, free: 2.441 MB / 282.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1135/0.1136, allocations: 51.48 MB / 402.1 MB, free: 14.91 MB / 346.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.3668/0.4804, allocations: 90.85 MB / 493 MB, free: 14.71 MB / 362.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0001794/0.4806, allocations: 74.41 kB / 493 MB, free: 14.67 MB / 362.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Electrical/Batteries/ParameterRecords/TransientData/CellData.mo:8:3-11:59:writable] Notification: Moving binding to initial equation section and setting fixed attribute of cellData2.rcData[2].R to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Electrical/Batteries/ParameterRecords/TransientData/CellData.mo:8:3-11:59:writable] Notification: Moving binding to initial equation section and setting fixed attribute of cellData2.rcData[2].C to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Electrical/Batteries/ParameterRecords/TransientData/CellData.mo:8:3-11:59:writable] Notification: Moving binding to initial equation section and setting fixed attribute of cellData2.rcData[1].R to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Electrical/Batteries/ParameterRecords/TransientData/CellData.mo:8:3-11:59:writable] Notification: Moving binding to initial equation section and setting fixed attribute of cellData2.rcData[1].C to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Electrical/Batteries/Examples/BatteryDischargeCharge.mo:52:5-52:23:writable] Error: Type mismatch in binding cellData = cellData2, expected subtype of record Modelica.Electrical.Batteries.ParameterRecords.TransientData.CellData String CellType; Real(displayUnit = "A.h", quantity = "ElectricCharge", unit = "C") Qnom; Boolean useLinearSOCDependency; Real(min = 0.0, quantity = "ElectricPotential", unit = "V") OCVmax; Real(min = 0.0, start = 0.0, quantity = "ElectricPotential", unit = "V") OCVmin; Real(max = 1.0) SOCmax; Real(min = 0.0) SOCmin; Real[2, 2] OCV_SOC; enumeration(LinearSegments, ContinuousDerivative, ConstantSegments, MonotoneContinuousDerivative1, MonotoneContinuousDerivative2, ModifiedContinuousDerivative) smoothness; Real[2, 2] OCV_SOC_internal; Real(quantity = "Resistance", unit = "Ohm") Ri; Real(quantity = "ThermodynamicTemperature", unit = "K", min = 0.0, start = 288.15, nominal = 300.0, displayUnit = "degC") T_ref; Real(quantity = "LinearTemperatureCoefficient", unit = "1/K") alpha; Real(quantity = "ElectricCurrent", unit = "A") Idis; Real(quantity = "Resistance", unit = "Ohm") R0; Integer nRC; record Modelica.Electrical.Batteries.ParameterRecords.TransientData.RCData String CellType; Real(quantity = "Resistance", unit = "Ohm") R; Real(quantity = "ThermodynamicTemperature", unit = "K", min = 0.0, start = 288.15, nominal = 300.0, displayUnit = "degC") T_ref; Real(quantity = "LinearTemperatureCoefficient", unit = "1/K") alpha; Real(quantity = "Capacitance", unit = "F", min = 0.0) C; end Modelica.Electrical.Batteries.ParameterRecords.TransientData.RCData;[1] rcData; end Modelica.Electrical.Batteries.ParameterRecords.TransientData.CellData;, got type record Modelica.Electrical.Batteries.ParameterRecords.TransientData.ExampleData$cellData2 String CellType; Real(displayUnit = "A.h", quantity = "ElectricCharge", unit = "C") Qnom; Boolean useLinearSOCDependency; Real(min = 0.0, quantity = "ElectricPotential", unit = "V") OCVmax; Real(min = 0.0, start = 0.0, quantity = "ElectricPotential", unit = "V") OCVmin; Real(max = 1.0) SOCmax; Real(min = 0.0) SOCmin; Real[29, 2] OCV_SOC; enumeration(LinearSegments, ContinuousDerivative, ConstantSegments, MonotoneContinuousDerivative1, MonotoneContinuousDerivative2, ModifiedContinuousDerivative) smoothness; Real[29, 2] OCV_SOC_internal; Real(quantity = "Resistance", unit = "Ohm") Ri; Real(quantity = "ThermodynamicTemperature", unit = "K", min = 0.0, start = 288.15, nominal = 300.0, displayUnit = "degC") T_ref; Real(quantity = "LinearTemperatureCoefficient", unit = "1/K") alpha; Real(quantity = "ElectricCurrent", unit = "A") Idis; Real(quantity = "Resistance", unit = "Ohm") R0; Integer nRC; record Modelica.Electrical.Batteries.ParameterRecords.TransientData.RCData String CellType; Real(quantity = "Resistance", unit = "Ohm") R; Real(quantity = "ThermodynamicTemperature", unit = "K", min = 0.0, start = 288.15, nominal = 300.0, displayUnit = "degC") T_ref; Real(quantity = "LinearTemperatureCoefficient", unit = "1/K") alpha; Real(quantity = "Capacitance", unit = "F", min = 0.0) C; end Modelica.Electrical.Batteries.ParameterRecords.TransientData.RCData;[2] rcData; end Modelica.Electrical.Batteries.ParameterRecords.TransientData.ExampleData$cellData2;. Error: Error occurred while flattening model Modelica.Electrical.Batteries.Examples.BatteryDischargeCharge Notification: Performance of FrontEnd: time 0.07182/0.5524, allocations: 27.64 MB / 0.5085 GB, free: 4.523 MB / 378.7 MB