Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case680.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case680,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case680",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case680,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case680",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.544/2.544, allocations: 390.3 MB / 402.8 MB, free: 6.648 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001428/0.001428, allocations: 188.9 kB / 496.1 MB, free: 12.86 MB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.969/1.969, allocations: 221.3 MB / 0.7915 GB, free: 5.406 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001124/0.001124, allocations: 87.91 kB / 0.9317 GB, free: 5.73 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 5.235e-05/5.311e-05, allocations: 4 kB / 1.079 GB, free: 140.4 MB / 0.7292 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4008/0.4009, allocations: 143 MB / 1.219 GB, free: 13.41 MB / 0.7448 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.347/7.748, allocations: 2.102 GB / 3.32 GB, free: 184.9 MB / 1.167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004774/7.749, allocations: 116 kB / 3.321 GB, free: 184.8 MB / 1.167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:181:3-189:69:writable] Error: Variable staRes: In modifier (minT(Min = 259.35), class or component Min), class or component minT not found in . Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case680 Notification: Performance of FrontEnd: time 1.577/9.326, allocations: 230 MB / 3.545 GB, free: 319.1 MB / 1.167 GB