Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,fileNamePrefix="Buildings_latest_Buildings_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_Validation_Analytic_20Years",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,fileNamePrefix="Buildings_latest_Buildings_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_Validation_Analytic_20Years",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.257/2.257, allocations: 390.3 MB / 402.8 MB, free: 6.664 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001271/0.001271, allocations: 180.7 kB / 496.1 MB, free: 12.86 MB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.629/1.629, allocations: 221.3 MB / 0.7915 GB, free: 5.363 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001158/0.001158, allocations: 79.98 kB / 0.9317 GB, free: 5.688 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 3.587e-05/3.591e-05, allocations: 4 kB / 1.079 GB, free: 140.4 MB / 0.7292 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3006/0.3007, allocations: 143 MB / 1.219 GB, free: 13.39 MB / 0.7448 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.054/1.355, allocations: 189.6 MB / 1.404 GB, free: 12.75 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003017/1.355, allocations: 102 kB / 1.404 GB, free: 12.69 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/GroundTemperatureResponse.mo:11:3-13:87:writable] Error: Array equation has unknown size in groTemRes.borFieDat.conDat.cooBor=borFieDat.conDat.cooBor. Error: Internal error - InstUtil.moveBindings: Mismatched number of equations and variables. Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years Notification: Performance of FrontEnd: time 0.03421/1.39, allocations: 11.8 MB / 1.416 GB, free: 3.082 MB / 0.8698 GB