Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr ThermoPower_ThermoPower.PowerPlants.Simulators.SteamPlant_Sim1.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo", uses=false) Using package ThermoPower with version 3.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(ThermoPower.PowerPlants.Simulators.SteamPlant_Sim1,tolerance=1e-06,outputFormat="empty",numberOfIntervals=6000,variableFilter="",fileNamePrefix="ThermoPower_ThermoPower.PowerPlants.Simulators.SteamPlant_Sim1") translateModel(ThermoPower.PowerPlants.Simulators.SteamPlant_Sim1,tolerance=1e-06,outputFormat="empty",numberOfIntervals=6000,variableFilter="",fileNamePrefix="ThermoPower_ThermoPower.PowerPlants.Simulators.SteamPlant_Sim1") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001539/0.001539, allocations: 180.6 kB / 8.344 MB, free: 0.7148 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.558/1.558, allocations: 205.3 MB / 214.1 MB, free: 14.14 MB / 187.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008747/0.0008747, allocations: 85.48 kB / 262.1 MB, free: 13.88 MB / 219.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo): time 0.398/0.398, allocations: 48.77 MB / 358.8 MB, free: 53.16 MB / 299.1 MB Notification: Performance of FrontEnd - loaded program: time 1.077e-05/1.09e-05, allocations: 0 / 425.3 MB, free: 8.227 MB / 315.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1053/0.1054, allocations: 60.25 MB / 485.5 MB, free: 11.82 MB / 379.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo:496:5-496:66:writable] Error: Base class ThermoPower.Electrical.Network1portBase not found in scope ThermoPower.Electrical.NetworkGrid_Pmax. Error: Error occurred while flattening model ThermoPower.PowerPlants.Simulators.SteamPlant_Sim1 Notification: Performance of FrontEnd: time 4.809/4.914, allocations: 2.409 GB / 2.883 GB, free: 96 kB / 0.5108 GB