Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Fluid.FMI.Validation.HeaterFan_noReverseFlow.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: translateModel(Buildings.Fluid.FMI.Validation.HeaterFan_noReverseFlow,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|hea.com.vol.T|sou.T_in",fileNamePrefix="Buildings_latest_Buildings.Fluid.FMI.Validation.HeaterFan_noReverseFlow") translateModel(Buildings.Fluid.FMI.Validation.HeaterFan_noReverseFlow,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|hea.com.vol.T|sou.T_in",fileNamePrefix="Buildings_latest_Buildings.Fluid.FMI.Validation.HeaterFan_noReverseFlow") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.366/2.366, allocations: 390.5 MB / 398 MB, free: 10.99 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001336/0.001336, allocations: 180.5 kB / 491.2 MB, free: 1.629 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.547/1.547, allocations: 221.5 MB / 0.7868 GB, free: 13.29 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001025/0.001026, allocations: 83.91 kB / 0.9269 GB, free: 13.79 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 1.75e-05/1.752e-05, allocations: 4 kB / 1.073 GB, free: 182.1 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3199/0.3199, allocations: 143 MB / 1.212 GB, free: 39.56 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.562/5.882, allocations: 1.969 GB / 3.181 GB, free: 359.1 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002582/5.882, allocations: 92.73 kB / 3.181 GB, free: 359 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$sou$outlet$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$floMac$inlet$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$floMac$outlet$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$floMac$bouIn$bacPro_internal is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$floMac$bouIn$inlet$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$floMac$bouOut$bacPro_internal is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$floMac$bouOut$outlet$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/BaseClasses/Euler/getPeak.mo:9:3-10:49:writable] Warning: Component peak in env: Buildings.Fluid.Movers.BaseClasses.Euler.getPeak has the same name as its type Buildings.Fluid.Movers.BaseClasses.Euler.peak. This is forbidden by Modelica specification and may lead to lookup errors. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/Data/Generic.mo:90:3-92:29:writable] Error: Class Buildings.Fluid.Movers.BaseClasses.Euler.getPeak not found in scope Buildings.Fluid.Movers.Data.Generic (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.FMI.Validation.HeaterFan_noReverseFlow Notification: Performance of FrontEnd: time 1.615/7.497, allocations: 363.3 MB / 3.536 GB, free: 302.4 MB / 1.151 GB