Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|noGai.bui.zon.TAir|radOnl.bui.zon.TAir|conOnl.bui.zon.TAir|latOnl.bui.zon.TAir|noGai.bui.zon.TRad|radOnl.bui.zon.TRad|conOnl.bui.zon.TRad|latOnl.bui.zon.TRad|noGai.bui.zon.phi|radOnl.bui.zon.phi|conOnl.bui.zon.phi|latOnl.bui.zon.phi|noGai.bui.zon.ports.1..Xi_outflow.1.|radOnl.bui.zon.ports.1..Xi_outflow.1.|conOnl.bui.zon.ports.1..Xi_outflow.1.|latOnl.bui.zon.ports.1..Xi_outflow.1.",fileNamePrefix="Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain") translateModel(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|noGai.bui.zon.TAir|radOnl.bui.zon.TAir|conOnl.bui.zon.TAir|latOnl.bui.zon.TAir|noGai.bui.zon.TRad|radOnl.bui.zon.TRad|conOnl.bui.zon.TRad|latOnl.bui.zon.TRad|noGai.bui.zon.phi|radOnl.bui.zon.phi|conOnl.bui.zon.phi|latOnl.bui.zon.phi|noGai.bui.zon.ports.1..Xi_outflow.1.|radOnl.bui.zon.ports.1..Xi_outflow.1.|conOnl.bui.zon.ports.1..Xi_outflow.1.|latOnl.bui.zon.ports.1..Xi_outflow.1.",fileNamePrefix="Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.163/2.163, allocations: 387.4 MB / 394.9 MB, free: 13.38 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001109/0.001109, allocations: 180.8 kB / 487.4 MB, free: 5.02 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.394/1.394, allocations: 221.5 MB / 0.7824 GB, free: 0.918 MB / 0.5417 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0007951/0.0007951, allocations: 95.88 kB / 0.9219 GB, free: 2.145 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 1.724e-05/1.726e-05, allocations: 4 kB / 1.067 GB, free: 185.7 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2444/0.2445, allocations: 142.4 MB / 1.206 GB, free: 43.93 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.888/5.132, allocations: 1.958 GB / 3.164 GB, free: 334.5 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002747/5.133, allocations: 97.05 kB / 3.164 GB, free: 334.5 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/ThermalZones/EnergyPlus_9_6_0/BaseClasses/ThermalZoneAdapter.mo:101:3-131:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain Notification: Performance of FrontEnd: time 1.616/6.749, allocations: 425.4 MB / 3.579 GB, free: 306.5 MB / 1.151 GB