Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: translateModel(Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow") translateModel(Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.602/1.602, allocations: 289.9 MB / 297.4 MB, free: 6.359 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00113/0.00113, allocations: 188.8 kB / 366.7 MB, free: 1.633 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.67/1.67, allocations: 205.2 MB / 0.626 GB, free: 7.168 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009434/0.0009436, allocations: 94.59 kB / 0.74 GB, free: 39.56 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.752e-05/1.754e-05, allocations: 4 kB / 0.8597 GB, free: 13.08 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6959/0.696, allocations: 116.3 MB / 0.9732 GB, free: 76.23 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.021/1.717, allocations: 422.7 MB / 1.386 GB, free: 134.3 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002264/1.717, allocations: 88.08 kB / 1.386 GB, free: 134.2 MB / 0.8542 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Chillers/Validation/Carnot_TEva_reverseFlow.mo:22:3-37:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow Notification: Performance of FrontEnd: time 0.1546/1.872, allocations: 83.62 MB / 1.468 GB, free: 64.34 MB / 0.8542 GB