Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.BaseClasses.Examples.InfraredRadiationExchange.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.BaseClasses.Examples.InfraredRadiationExchange,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.ThermalZones.Detailed.BaseClasses.Examples.InfraredRadiationExchange") Notification: Performance of loadModel(Buildings): time 4.063/4.063, allocations: 433.4 MB / 440.9 MB, free: 10.46 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 1.83e-05/1.841e-05, allocations: 4 kB / 0.5325 GB, free: 1.969 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5092/0.5093, allocations: 98.72 MB / 0.6289 GB, free: 15.75 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.2265/0.7358, allocations: 146.3 MB / 0.7718 GB, free: 13.28 MB / 0.6511 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002923/0.7362, allocations: 91.94 kB / 0.7718 GB, free: 13.19 MB / 0.6511 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/ThermalZones/Detailed/BaseClasses/Examples/InfraredRadiationExchange.mo:13:11-13:36:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.BaseClasses.Examples.InfraredRadiationExchange Notification: Performance of FrontEnd: time 0.7252/1.461, allocations: 50.13 MB / 0.8208 GB, free: 148.5 MB / 0.6667 GB