Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb") Notification: Performance of loadModel(Buildings): time 3.816/3.816, allocations: 433.4 MB / 440.9 MB, free: 10.46 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 2.286e-05/2.299e-05, allocations: 4 kB / 0.5325 GB, free: 1.941 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4976/0.4976, allocations: 98.71 MB / 0.6289 GB, free: 15.72 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.01/6.508, allocations: 2.494 GB / 3.123 GB, free: 262.9 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000251/6.508, allocations: 102.4 kB / 3.123 GB, free: 262.8 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-12:61:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/HeatExchangers/CoolingTowers/Examples/BaseClasses/PartialStaticTwoPortCoolingTower.mo:11:3-20:71:writable] Error: component tow contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb Notification: Performance of FrontEnd: time 1.3/7.808, allocations: 283.1 MB / 3.399 GB, free: 187.2 MB / 0.823 GB