Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition") Notification: Performance of loadModel(Buildings): time 3.836/3.836, allocations: 433.4 MB / 440.9 MB, free: 10.36 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 2.211e-05/2.213e-05, allocations: 8 kB / 0.5326 GB, free: 1.816 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4895/0.4895, allocations: 98.7 MB / 0.6289 GB, free: 15.7 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.1878/0.6774, allocations: 124 MB / 0.75 GB, free: 3.547 MB / 0.6198 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003027/0.6777, allocations: 107.9 kB / 0.7501 GB, free: 3.441 MB / 0.6198 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/LoadAggregation/Validation/TemporalSuperposition.mo:5:3-9:41:writable] Error: No matching function found for Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.temporalSuperposition(6, {2.0, 1000000.0, 3.0, 1000000.0, 1000000.0}, {0.4, 0.0, 0.2, 1.0, 0.0}, 3) of type .Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.temporalSuperposition(Integer i, Real(quantity = "Power", unit = "W")[i] QAgg_flow, Real(quantity = "ThermalResistance", unit = "K/W")[i] kappa, Integer curCel) => Real(quantity = "ThermodynamicTemperature", unit = "K") in component candidates are .Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.temporalSuperposition(Integer i, Real(quantity = "Power", unit = "W")[i] QAgg_flow, Real(quantity = "ThermalResistance", unit = "K/W")[i] kappa, Integer curCel) => Real(quantity = "ThermodynamicTemperature", unit = "K") Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition Notification: Performance of FrontEnd: time 0.0009409/0.6787, allocations: 0.4933 MB / 0.7506 GB, free: 2.945 MB / 0.6198 GB