Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer") Notification: Performance of loadModel(Buildings): time 3.825/3.825, allocations: 433.4 MB / 440.9 MB, free: 10.37 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 1.546e-05/1.555e-05, allocations: 3.984 kB / 0.5325 GB, free: 1.844 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4863/0.4863, allocations: 98.71 MB / 0.6289 GB, free: 15.69 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.358/6.845, allocations: 2.654 GB / 3.283 GB, free: 41.21 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002706/6.845, allocations: 104.8 kB / 3.283 GB, free: 41.15 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumCW[2].pressure.V_flow={0.006940000000000001, 0.02082, 0.0347, 0.04164}. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumCW[1].pressure.V_flow={0.006940000000000001, 0.02082, 0.0347, 0.04164}. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumPri[2].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumPri[1].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumSec[2].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumSec[1].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Applications/DataCenters/ChillerCooled/Examples/BaseClasses/PartialDataCenter.mo:121:5-121:17:writable] Error: Type mismatch in binding hydraulicEfficiency = Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency({0}, {0.7}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[1] V_flow; Real(max = 1.0, quantity = "Efficiency", unit = "1", min = 0.0)[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency Integer[1] V_flow; Real[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer Notification: Performance of FrontEnd: time 5.128/11.97, allocations: 1.092 GB / 4.376 GB, free: 93.09 MB / 0.8542 GB