Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb,fileNamePrefix="Buildings_latest_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_FixedApproachWetBulb",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb,fileNamePrefix="Buildings_latest_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_FixedApproachWetBulb",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.388/2.388, allocations: 390.5 MB / 398 MB, free: 10.98 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001082/0.001082, allocations: 188.8 kB / 491.2 MB, free: 1.609 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.639/1.639, allocations: 221.5 MB / 0.7868 GB, free: 13.34 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001029/0.00103, allocations: 91.89 kB / 0.9269 GB, free: 13.84 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 2.986e-05/2.987e-05, allocations: 10.03 kB / 1.073 GB, free: 182 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3433/0.3434, allocations: 143 MB / 1.212 GB, free: 39.43 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.537/6.88, allocations: 2.227 GB / 3.439 GB, free: 51.4 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003158/6.881, allocations: 100.2 kB / 3.439 GB, free: 51.35 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/BaseClasses/Euler/getPeak.mo:9:3-10:49:writable] Warning: Component peak in env: Buildings.Fluid.Movers.BaseClasses.Euler.getPeak has the same name as its type Buildings.Fluid.Movers.BaseClasses.Euler.peak. This is forbidden by Modelica specification and may lead to lookup errors. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/Data/Generic.mo:90:3-92:29:writable] Error: Class Buildings.Fluid.Movers.BaseClasses.Euler.getPeak not found in scope Buildings.Fluid.Movers.Data.Generic (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb Notification: Performance of FrontEnd: time 1.443/8.324, allocations: 325.5 MB / 3.757 GB, free: 186.1 MB / 1.151 GB