startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./ThermofluidStream_ThermofluidStream.FlowControl.Tests.PCV -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS stdout | info | The initialization finished successfully without homotopy method. assert | warning | The following assertion has been violated at time 0.196000 | | | | pCV1.inlet.m_flow > volumeFlex.m_flow_assert assert | error | Negative massflow at Volume inlet stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 0.195900 | | | | pCV1.inlet.m_flow > volumeFlex.m_flow_assert assert | error | Negative massflow at Volume inlet stdout | info | model terminate | Simulation terminated by an assert at time: 0.1959 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00702601s reading init.xml | | | | | | 0.000608771s reading info.xml | | | | | | 0.000348894s pre-initialization | | | | | | 0.000132369s [ 0.6%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.000659111s [ 2.9%] creating output-file | | | | | | 6.9928e-05s [ 0.3%] event-handling | | | | | | 0.00311243s [ 13.6%] overhead | | | | | | 0.0185664s [ 81.1%] simulation | | | | | | 0.0228891s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 252 steps taken | | | | | | 348 calls of functionODE | | | | | | 51 evaluations of jacobian | | | | | | 14 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00226974s time of jacobian evaluation